
Heavy-Duty Container Construction
The 1600 kW package travels inside a 40HQ container, everything bolted to an internal steel base. Routine service is carried out through the container doors and the reserved access panels.
Container type silent generator set is designed to deliver reliable power with low noise, high efficiency, and strong durability. Built with a modular containerized structure, it integrates advanced soundproofing technology, ventilation optimization, and anti-vibration design to ensure stable operation even under harsh working environments. With a power range of1000kw-2500kw, this generator is suitable for continuous and emergency applications, providing dependable performance for industrial, commercial, and large-scale projects.
|
1600 kW
Prime power
|
|
1760 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
1600 kW prime / 1760 kW standby — 2000 kVA — built as a 40HQ container package package for utility-scale and multi-unit project power.
The Outevo 1600 kW Containerized Diesel Generator Set is used for utility and IPP projects, multi-megawatt industrial plants, mine and port power stations, typically base-load duty, often in multi-unit parallel configuration. Loads are normally MV switchgear interface for the 1600 kW installations and multi-unit busbars.
Every unit is assembled and load-tested on our own production line for the 1600 kW classs. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas sets including this 1600 kW rating generator sets since 2006 from a 20,000 m² production base in Shandong with a fully automatic line, and more than 2,000 sets have been delivered to over 100 countries.
Protection on the 1600 kW set is IP23 or higher, upgradable for dusty, humid, rainy or high-temperature sites.

The 1600 kW package travels inside a 40HQ container, everything bolted to an internal steel base. Routine service is carried out through the container doors and the reserved access panels.

Declared output is 1600 kW prime and 1760 kW standby (2000 kVA) at 380/220 V, 50 Hz, 1500 rpm. Design duty is base-load duty, often in multi-unit parallel configuration with MV switchgear interface for the 1600 kW installations and multi-unit busbars.

At 1600 kW the diesel engine is selected from Cummins, Perkins, Weichai and Yuchai, then matched and aligned to the alternator before full-load testing in our own facility.

Closed-circuit water cooling with forced fan and a large water tank is specified for the 1600 kW set, which stabilises temperature in high ambient and continuous load duty.

The 1600 kW set carries sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher, with uprated protection available for severe sites.

ATS, remote monitoring module, cable winch and quick connectors can be specified on the 1600 kW set; the control, protection and voltage settings are configured to the project specification.
Standard 40HQ container package configuration at 1600 kW prime / 1760 kW standby (2000 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiDiesel engines on the 1600 kW set are selected from these Tier-1 platforms and matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 1600 kW set, an optional automatic transfer switch for automatic standby start, plus an optional remote monitoring module. The control and protection scheme on the 1600 kW set is set to your project specification. |
Build configurationThis model ships as a 40HQ containerized setThis model ships as a 40HQ containerized set. Open frame, silent and mobile configurations are available across the 10–3,750 kVA range under OEM/ODM terms. |
1. UtilityWhere utility and IPP projects is the load, the 1600 kW rating is normally specified at base-load duty, often in multi-unit parallel configuration. Base-load duty means the 1600 kW rating is specified for continuous operation, not standby only. |
2. Multi-megawatt industrial plantsThe 1600 kW containerized diesel generator set set suits multi-megawatt industrial plants. Duty is base-load duty, often in multi-unit parallel configuration. Multi-unit parallel operation and load sharing on the 1600 kW park are part of the normal project scope. |
3. MineMine and port power stations is a standard application for the 1600 kW unit, which runs at base-load duty, often in multi-unit parallel configuration. MV switchgear interface for the 1600 kW installation and protection coordination are fixed with the project electrical design. |
4. Gas engine power plantsThe 1600 kW set is commonly applied to gas engine power plants at base-load duty, often in multi-unit parallel configuration. Fuel or gas supply and day tanks for the 1600 kW set and safety systems are engineered as part of the package. |
5. District energyFor district energy and CHP schemes the 1600 kW rating covers utility-scale and multi-unit project power at base-load duty, often in multi-unit parallel configuration. Site ambient, altitude and humidity derating are applied to the declared 1600 kW rating. |
6. National infrastructure programmesWhere national infrastructure programmes is the load, the 1600 kW rating is normally specified at base-load duty, often in multi-unit parallel configuration. Commissioning and load-bank testing of the 1600 kW unit and operator training are normally included in the scope. |
The same engineering and testing standard applies to this 1600 kW rating in all three builds — the difference is enclosure, access and transport.
| This model · 1600 kW containerized diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All containerized sets |
Send us the required power for the 1600 kW set, voltage and frequency and we will return a configuration.
Tell us the rating, voltage and frequency you need for the 1600 kW unit and where it is going. Our engineering team returns a configuration and quotation.
Our representative will contact you soon.