Heavy-Duty Natural Gas Construction
A fabricated base carries the 600 kW gas engine, alternator and control panel on anti-vibration mounts, with piping, wiring and instrumentation completed before shipment.
The silent gas generator set is specially designed to deliver clean low-carbon, quiet stable, efficient and durable power supply. Adopting an integrated compact structure, it integrates professional sound insulation and noise reduction technology, intelligent ventilation and heat dissipation system, and multi-stage anti-vibration buffer design, balancing environmental friendliness, reliability and operation and maintenance convenience.
|
600 kW
Prime power
|
|
660 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
Rated 600 kW prime and 660 kW standby at 750 kVA, supplied as a natural gas package unit for heavy industrial and project power.
Where it is installed — district cooling and chiller plants, hospitals and institutional campuses, oil and gas field facilities — the 600 kW set works at continuous prime duty at high load factor. Distribution for the 600 kW set is usually through main switchboards with motor-starting and step-load duty.
Each 600 kW set is assembled and load-tested in our own works. Outevo has produced diesel and gas sets including this 600 kW rating generating sets since 2006 from a 20,000 m² production base in Shandong with a fully automatic line, and has delivered more than 2,000 sets to over 100 countries.
IP23 or higher protection is standard on the 600 kW set, with higher grades available for dust, humidity, rain or heat.

A fabricated base carries the 600 kW gas engine, alternator and control panel on anti-vibration mounts, with piping, wiring and instrumentation completed before shipment.

The 600 kW prime / 660 kW standby rating is declared at 380/220 V, 50 Hz, 1500 rpm (750 kVA), intended for continuous prime duty at high load factor across main switchboards with motor-starting and step-load duty.

Engine options for the 600 kW gas set are Cummins and Weichai; whichever is specified, the engine is matched to the alternator and load-tested in our own works.

The 600 kW package uses closed water-cooling with forced ventilation and a large-capacity tank, holding temperatures steady during extended continuous duty in hot climates.

Enclosure sealing and anti-corrosion finishing are rated IP23 or higher on the 600 kW set, upgradable for harsher sites, treating dust, rain, snow and temperature extremes as normal conditions.

Options on the 600 kW set include an automatic transfer switch, remote monitoring, cable winch and quick connectors; base-frame arrangement and control, protection and voltage settings are set to the project specification.
Standard natural gas package configuration at 600 kW prime / 660 kW standby (750 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiFor the 600 kW set the engine is drawn from these Tier-1 platforms and matched to the alternator, with the final platform fixed at order stage. |
Control & protectionATS & remote monitoringAn automatic transfer switch and remote monitoring module can be specified on the 600 kW set. The control and protection scheme on the 600 kW set is configured to the project specification. |
Build configurationNatural Gas standardNatural Gas standard |
1. Process plantsProcess plants and heavy machinery is a standard application for the 600 kW unit, which runs at continuous prime duty at high load factor. High load factor means the 600 kW rating is checked against continuous duty rather than peak only. |
2. MiningThe 600 kW set is commonly applied to mining and aggregate sites at continuous prime duty at high load factor. Large motor starts and step loads drive the alternator sizing at 600 kW. |
3. District coolingFor district cooling and chiller plants the 600 kW rating covers heavy industrial and project power at continuous prime duty at high load factor. Parallel operation and load sharing on the 600 kW set are normally specified where redundancy is required. |
4. HospitalsWhere hospitals and institutional campuses is the load, the 600 kW rating is normally specified at continuous prime duty at high load factor. Main switchboard interface for the 600 kW set and protection coordination are reviewed with the site electrical design. |
5. OilThe 600 kW natural gas generator set set suits oil and gas field facilities. Duty is continuous prime duty at high load factor. Fuel storage and day-tank arrangement for the 600 kW set are confirmed against the project fire and safety scheme. |
6. Large construction packagesLarge construction packages is a standard application for the 600 kW unit, which runs at continuous prime duty at high load factor. Ambient and altitude derating for the 600 kW set are applied where the site sits above sea-level design conditions. |
This 600 kW rating is engineered and tested to one standard across the three builds — what changes is enclosure, access and transport.
| This model · 600 kW natural gas generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All natural gas sets |
Tell us the rating, voltage and frequency for the 600 kW unit and we will confirm a configuration.
Send the voltage and frequency you need with the 600 kW rating and the site location, and our engineering team returns a configuration and quotation.