L
O
A
D
I
N
G

Get a Free Quote

Our representative will contact you soon.
Name
Email
Company Name
Country
Mobile/WhatsApp
Required Power
Application
Project Details
0/1000
Container generator set

1200kW High Capacity Container Power Station Soundproof Dustproof for Large Scale Mining Industrial & Data Center Operations

Container type silent generator set is designed to deliver reliable power with low noise, high efficiency, and strong durability. Built with a modular containerized structure, it integrates advanced soundproofing technology, ventilation optimization, and anti-vibration design to ensure stable operation even under harsh working environments. With a power range of1000kw-2500kw, this generator is suitable for continuous and emergency applications, providing dependable performance for industrial, commercial, and large-scale projects.

Brand:
Outevo
  • Overview
  • Recommended Products
Containerized Diesel Generator Set · 1200 kW Prime / 1320 kW Standby

A 1200 kW containerized diesel generator set for oil and gas sites

One platform, four build types — open frame, silent canopy, containerized or trailer-mounted — configured to your site, your fuel and your duty. Tell us the load and the site, and we will confirm the build type, rating and lead time.

1200 kWPrime power1320 kWStandby power380/220 VRated voltage50 HzRated frequency1500 rpmRated speedIP23Protection grade
Manufacturing since 20062,000+ sets delivered100+ countriesLoad-tested before shipment
1200 kW
Prime power
1320 kW
Standby power
380/220 V
Rated voltage
2006+
Manufacturer since
Product overview

Heavy-duty containerized diesel generator sets for sites without a reliable grid

One 40HQ container package package, 1200 kW prime and 1320 kW standby (1500 kVA), aimed at heavy industrial and project power.

This 1200 kW Containerized Diesel Generator Set is specified for mining and aggregate sites, district cooling and chiller plants, hospitals and institutional campuses. Typical duty for the 1200 kW set is continuous prime duty at high load factor, feeding main switchboards with motor-starting and step-load duty.

Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 1200 kW class generator sets since 2006 at a 20,000 m² manufacturing facility served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.

The 1200 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

  • ✓1200 kW prime / 1320 kW standby at 380/220 V, 50 Hz, 1500 rpm
  • ✓Full service access — service through container doors and reserved access panels
  • ✓Tier-1 diesel engine platforms — Cummins, Perkins, Weichai and Yuchai
  • ✓Closed water-cooling with forced fan and large-capacity water tank
  • ✓IP23 or higher, upgradable for dust, humidity, rain and heat
Product features

Engineered for site conditions, not for the showroom

Heavy-Duty Container Construction

Heavy-Duty Container Construction

The 1200 kW package is assembled and tested as a single unit, so wellsite installation is limited to setting it on its base, connecting fuel and cabling and commissioning the panel.

1200 kW Prime / 1320 kW Standby Duty

1200 kW Prime / 1320 kW Standby Duty

Design duty at 1200 kW prime and 1320 kW standby is long continuous running with occasional hard starting of pump and compressor loads, rather than short standby bursts.

Tier-1 Diesel Engine Platforms

Tier-1 Diesel Engine Platforms

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms, then matched to the alternator and load-tested before the enclosure is closed.

Closed Water-Cooling with Forced Fan

Closed Water-Cooling with Forced Fan

Closed-circuit water cooling with forced fan and a large water tank is specified for high ambient fields, where sustained heat is the limiting factor rather than the rating itself.

Industrial Protection and Environmental Adaptability

Industrial Protection and Environmental Adaptability

Sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher is standard, with uprated protection for salt-laden, humid or desert conditions.

Flexible Configuration and Fast Deployment

Flexible Configuration and Fast Deployment

ATS, remote monitoring, cable winch and quick connectors can be specified so the set can be repositioned between wellsites or gathering stations without re-terminating the load.

Specifications

Technical data — 1200 kW containerized diesel generator set

Standard 40HQ container package configuration at 1200 kW prime / 1320 kW standby (1500 kVA). Ratings, voltage and frequency are confirmed at specification.

Related parameters Parameter values
Power Capacity Prime Power: 1200 kW   Standby Power: 1320 kW
Rated Voltage 380/220 Volts
Rated Current Issued with the approved data sheet for the selected build
Rated Frequency 50 Hertz
Rated Speed 1500 rpm
Fuel Type Diesel
Protection Grade IP23 or higherUpgradable upon customization

Values above are published for the standard containerized build at 1200 kW prime / 1,500 kVA, enclosure 12,192 × 2,438 × 2,896 mm. Refer to the approved drawing for your build before installation design.

Engine & options

Specify the engine platform, control scheme and build

Engine platform

Cummins · Perkins · Weichai · Yuchai

Engines on the 1200 kW set are selected from the Cummins, Perkins, Weichai and Yuchai platforms and matched to the alternator; the platform for your order is confirmed at order stage.

Control & protection

ATS & remote monitoring

On the 1200 kW set the control scheme can include an optional automatic transfer switch and remote monitoring module, with protection set for unattended operation.

Build configuration

Containerized standard

This model ships as a containerized set. Containerized, mobile and open frame builds of the same rating are available under OEM/ODM terms.

Applications

Where this 1200 kW containerized diesel generator set is used

1. Wellsite and drilling support

Carries mud pumps, winches, lighting and accommodation loads where rig power has to be generated on location.

2. Gathering stations and pumping

Provides continuous power for gathering-station pumps, compressor packages and metering skids along the route.

3. SCADA and telemetry cabinets

Backs up instrumentation, RTUs and telemetry so the control room keeps visibility of the field through an outage.

4. Tank farms and loading terminals

Stands by for transfer pumps, loading arms and vapour recovery, started automatically when the grid drops.

5. Turnaround and shutdown work

Supplies temporary power during maintenance windows, keeping instrument air, lighting and critical control loads live.

6. Remote camps and control buildings

Runs long prime-power cycles for camps and control buildings where the generator is the primary source rather than a backup.

Compare configurations

Open frame, silent or containerized?

Whichever build is chosen for the 1200 kW rating, engineering and testing are identical; only the enclosure, access and transport change.

Consideration Containerized (this model) Silent Containerized
Enclosure Open steel base frame, no canopy Soundproof canopy 40HQ container shell
Service access Unrestricted — no panels to remove for routine maintenance Through canopy access doors and monitoring windows Through container doors and reserved access panels
Noise control Not attenuated — containerized layout Multi-stage silencing structure and sound-absorbing materials Container shell combined with silencing
Weight and transport Lightest of the three builds Heavier than containerized Container handling and ocean freight
Typical duty Prime power on site; standby for factories and buildings Noise-sensitive locations such as residential, commercial and healthcare sites Rapid transport and deployment, remote and long-duration sites
Rated power of this model 1200 kW prime / 1320 kW standby Quoted per project Quoted per project
Protection grade IP23 or higher, upgradable Upgradable upon customization Upgradable upon customization
Minimum order quantity 1 set Quoted per project Quoted per project
This model · 1200 kW containerized diesel generator set
Range · 10–3,750 kVA
Diesel & gas
Open frame · silent · containerized · mobile
All containerized sets

Give us the power for the 1200 kW set, voltage and frequency and we will come back with a configuration.

FAQ

Frequently asked questions about this 1200 kW containerized diesel generator set

What power rating does this generator set provide?
This model is rated 1200 kW (1,500 kVA) prime and 1320 kW standby, with the KTA50-GS8 engine and a containerized build measuring 12,192 × 2,438 × 2,896 mm. Voltage, frequency and protection are configured to your project specification.
Which diesel engines are available for this set?
The standard build for this rating is a containerized set for sites where the unit stands near accommodation or a control room. Open frame, containerized and mobile builds are also available under OEM/ODM terms.
Open frame, silent or containerized — how do I choose?
Enclosure choice follows the location, not the rating. At 1200 kW the containerized build is normally used where the set stands near accommodation or a control room; open frame and trailer builds use the same engine and alternator.
Can the voltage and frequency be customised?
Yes. 380/220 V and 50 Hz are the published standard for the 1200 kW rating, and voltage and frequency are configured to the field specification under OEM/ODM terms.
What is the minimum order quantity?
One set can be ordered for a single wellsite. Where several locations share a fleet, parallel operation and load sharing are configured so units can be moved between them.
How is the quality of each unit assured?
Every 1200 kW set is assembled and load-tested on our own production lines before shipment and travels with a data sheet and test record. Shanghai Outevo Machinery Co., Ltd. has manufactured generator sets since 2006, with more than 2,000 units delivered to over 100 countries.
Get a quote

Configure your 1200 kW containerized diesel generator set

Give us the voltage and frequency for the 1200 kW set and the destination site; our engineering team comes back with a configuration and quotation.

What we need from you

  • Required power rating — this model or another rating in the 10–3,750 kVA range
  • Voltage and frequency settings for your site
  • Prime power or standby duty, and the application
  • Destination port and required quantity

Request a quote

Our representative will contact you soon.

Your configuration: 1200 kW containerized diesel generator set (this model), 380/220 V, 50 Hz

OEM/ODM and custom builds at 1200 kW are quoted against the project specification.

2006+
Manufacturing since
100+
Countries served
2,000+
Sets delivered
20,000 m²
Manufacturing facility



Email: [email protected]

Phone: +86-13280035385

Get a Free Quote

Our representative will contact you soon.
Name
Email
Company Name
Country
Mobile/WhatsApp
Required Power
Application
Project Details
0/1000