Heavy-Duty Natural Gas Construction
The 300 kW package is supplied as one assembled unit, so the installation in a service yard or plant room is a positioning, fuel and cabling task rather than a build.
The silent gas generator set is specially designed to deliver clean low-carbon, quiet stable, efficient and durable power supply. Adopting an integrated compact structure, it integrates professional sound insulation and noise reduction technology, intelligent ventilation and heat dissipation system, and multi-stage anti-vibration buffer design, balancing environmental friendliness, reliability and operation and maintenance convenience.
|
300 kW
Prime power
|
|
330 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
300 kW prime / 330 kW standby — 375 kVA — built as a natural gas package package for mid-size industrial and site power.
Offices, retail and mixed-use buildings need a supply that carries services without becoming a nuisance to tenants or neighbours. This 300 kW silent set (375 kVA prime, 330 kW standby) is specified for that role. The critical loads are lifts, HVAC, pumps and building management, all started at once when the mains drops. The 6ZTAA13-G3 engine is matched to the 300 kW rating with headroom for those starting surges.
Every unit is assembled and load-tested on our own production line for the 300 kW class. The unit is enclosed in a sound-absorbing canopy measuring 4,800 × 1,380 × 2,240 mm and protected to IP23 or higher, so it can be installed in a service yard or basement plant room. Each set is load-tested before shipment. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas generator sets since 2006 from a 20,000 m² manufacturing facility, and more than 2,000 sets have been delivered to over 100 countries.
Protection on the 300 kW set is IP23 or higher, upgradable for dusty, humid, rainy or high-temperature sites.

The 300 kW package is supplied as one assembled unit, so the installation in a service yard or plant room is a positioning, fuel and cabling task rather than a build.

Design duty at 300 kW prime and 330 kW standby covers lifts, HVAC and pumps starting together, which is the sizing case rather than the steady running load.

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms, aligned to the alternator and fully load-tested before shipment.

Closed-circuit water cooling with forced fan and a large water tank keeps the set stable while it carries building services through an outage.

Sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher, with alarm contacts available for building management systems.

ATS, remote monitoring and quick connectors can be specified so the transition is automatic and the facilities team is alerted remotely.
Standard natural gas package configuration at 300 kW prime / 330 kW standby (375 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiEngines on the 300 kW set are drawn from the Cummins, Perkins, Weichai and Yuchai platforms and matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 300 kW set an optional automatic transfer switch and remote monitoring module allow unattended starting, with protection set for a managed property. |
Build configurationNatural Gas standardThis model ships as a silent set. Open frame, containerized and mobile builds of the same rating are available under OEM/ODM terms. |
1. Lifts and building transportKeeps lift service available so occupants can leave and enter the building normally during an outage. |
2. HVAC and ventilationKeeps air handling and ventilation running in occupied floors and car parks. |
3. Water booster and drainage pumpsCarries domestic water boosters and sump pumps so services continue without manual intervention. |
4. Lobby, car park and facade lightingSupplies the lighting required for circulation and security in commercial premises. |
5. Fire and life-safety systemsBacks up fire pumps, smoke control and alarm panels required for safe occupancy. |
6. Tenant IT and comms roomsSupplies tenant comms cabinets and building IT rooms where loss of service is immediately visible. |
The same engineering and testing standard applies to this 300 kW rating in all three builds — the difference is enclosure, access and transport.
| This model · 300 kW natural gas generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All natural gas sets |
Send us the required power for the 300 kW set, voltage and frequency and we will return a configuration.
Tell us the rating, voltage and frequency you need for the 300 kW unit and where it is going. Our engineering team returns a configuration and quotation.
Our representative will contact you soon.