Heavy-Duty Silent Construction
The 70 kW package is delivered assembled on its base frame, so installation at basement level or in a service yard is limited to positioning, fuel connection and cabling.
Silent generator sets are designed to deliver stable power output with ultra-low noise levels, making them the ideal choice for residential, commercial, and industrial applications. With advanced soundproof technology, durable steel enclosures, and high-efficiency engines, our generator sets provide reliable electricity while minimizing environmental impact.
|
70 kW
Prime power
|
|
77 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
70 kW prime / 77 kW standby — 88 kVA — built as a soundproof canopy set package for small commercial and light industrial.
A hotel or commercial building cannot be evacuated for a two-hour outage, and guests notice a noisy set immediately. This 70 kW silent set (87 kVA prime, 77 kW standby) is specified for that combination. The load profile is dominated by HVAC, lifts and domestic water, all of which have high starting currents. The 4BTA3.9-G11 engine is matched to the 70 kW rating and the enclosure is lined to keep noise inside it.
Every unit is assembled and load-tested on our own production line for the 70 kW class. The silent build measures 2,920 × 1,100 × 1,890 mm, so the set can be installed at basement level or in a service yard close to occupied areas. Every unit is assembled and load-tested on our production lines. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas generator sets since 2006 from a 20,000 m² manufacturing facility, and more than 2,000 sets have been delivered to over 100 countries.
Protection on the 70 kW set is IP23 or higher, upgradable for dusty, humid, rainy or high-temperature sites.

The 70 kW package is delivered assembled on its base frame, so installation at basement level or in a service yard is limited to positioning, fuel connection and cabling.

Design duty at 70 kW prime and 77 kW standby covers lifts, HVAC and domestic water, which start together when the mains drops and set the sizing case for the alternator.

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms, matched to the alternator and load-tested before shipment.

Closed-circuit water cooling with forced fan and a large water tank holds temperature through an outage when the set is running at high load in a plant room.

Sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher, with fire-system and BMS interfaces available so the set reports into the building panel.

ATS, remote monitoring and quick connectors can be specified so the set starts automatically and the front desk is not the first to notice the supply has failed.
Standard soundproof canopy set configuration at 70 kW prime / 77 kW standby (88 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiEngines on the 70 kW set come from the Cummins, Perkins, Weichai and Yuchai platforms and are matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 70 kW set an optional automatic transfer switch and remote monitoring module give unattended starting, with protection configured to the building scheme. |
Build configurationSilent canopy standardThis model ships as a silent set. Containerized, mobile and open frame builds of the same rating are available under OEM/ODM terms. |
1. Lifts and escalatorsKeeps vertical transport available during an outage, including the motor starting surge of each lift as it re-starts. |
2. HVAC and guest-room servicesCarries chillers, air handling units and room controls so occupied rooms remain usable. |
3. Domestic water and boilersRuns booster pumps and boiler controls for hot water, the load guests notice first when it stops. |
4. Kitchen, laundry and cold roomsProtects refrigerated stores and keeps kitchen and laundry equipment running through the outage. |
5. Lobby, corridor and façade lightingSupplies the lighting levels needed for safe circulation in public areas. |
6. Fire, lifts and BMSBacks up fire pumps, lift control and building management systems required for safe occupancy. |
The same engineering and testing standard applies to this 70 kW rating in all three builds — the difference is enclosure, access and transport.
| This model · 70 kW silent diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All silent sets |
Send us the required power for the 70 kW set, voltage and frequency and we will return a configuration.
Tell us the rating, voltage and frequency you need for the 70 kW unit and where it is going. Our engineering team returns a configuration and quotation.