Heavy-Duty Container Construction
The 1000 kW package arrives as one unit with the enclosure, base frame and control panel already assembled, so installation work on site is limited to positioning, cabling and commissioning.
Container type silent generator set is designed to deliver reliable power with low noise, high efficiency, and strong durability. Built with a modular containerized structure, it integrates advanced soundproofing technology, ventilation optimization, and anti-vibration design to ensure stable operation even under harsh working environments. With a power range of1000kw-2500kw, this generator is suitable for continuous and emergency applications, providing dependable performance for industrial, commercial, and large-scale projects.
|
1000 kW
Prime power
|
|
1100 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
One 40HQ container package package, 1000 kW prime and 1100 kW standby (1250 kVA), aimed at heavy industrial and project power.
This 1000 kW Containerized Diesel Generator Set is specified for mining and aggregate sites, district cooling and chiller plants, hospitals and institutional campuses. Typical duty for the 1000 kW set is continuous prime duty at high load factor, feeding main switchboards with motor-starting and step-load duty.
Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 1000 kW class generator sets since 2006 at a 20,000 m² manufacturing facility served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.
The 1000 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

The 1000 kW package arrives as one unit with the enclosure, base frame and control panel already assembled, so installation work on site is limited to positioning, cabling and commissioning.

Design duty at 1000 kW prime and 1100 kW standby is standby operation with a hard step load, which is why the alternator is matched against starting kVA rather than running kW alone.

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms and aligned to the alternator before full-load testing, which is the test that proves the step-load response.

Closed-circuit water cooling with forced fan and a large water tank keeps coolant temperature stable during long idle periods interrupted by sudden load, a pattern typical of data centre standby.

Sealed dustproof and anti-corrosion treatment to IP23 or higher, with fire-system and alarm interfaces available so the set integrates with the building life-safety scheme.

ATS, remote monitoring and synchronising options can be specified; where two or more units share the load, control and load-sharing settings are configured to the site scheme.
Standard 40HQ container package configuration at 1000 kW prime / 1100 kW standby (1250 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiEngines on the 1000 kW set come from the Cummins, Perkins, Weichai and Yuchai platforms and are matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 1000 kW set an optional automatic transfer switch and remote monitoring module are available, so the transition happens without an operator on site. |
Build configurationThis model ships as a 40HQ containerized setThis model ships as a containerized set. Open frame, containerized and mobile builds of the same rating are available under OEM/ODM terms. |
1. IT and UPS supportTakes over the critical bus when the utility fails, carrying servers, storage and network equipment through an outage of any duration. |
2. Cooling and chilled-water plantDrives chillers, pumps and CRAC units so heat rejection continues after the mains drops, which is what actually protects the IT load. |
3. Automatic transfer and parallelingStarted through an optional ATS or a synchronising panel so the transition happens without an operator on site. |
4. Edge and container sitesSized for remote edge nodes where the incoming supply is one feed only and the generator is the sole backup. |
5. Maintenance and load-bank testingSupports scheduled testing with resistive load banks so the set is proven at rated load rather than idled. |
6. Fire, access and security systemsKeeps fire suppression, access control and CCTV live during an outage, including the period before the mains returns. |
Whichever build is chosen for the 1000 kW rating, engineering and testing are identical; only the enclosure, access and transport change.
| This model · 1000 kW containerized diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All containerized sets |
Give us the power for the 1000 kW set, voltage and frequency and we will come back with a configuration.
Give us the voltage and frequency for the 1000 kW set and the destination site; our engineering team comes back with a configuration and quotation.
Our representative will contact you soon.