Heavy-Duty Open Frame Construction
The 100 kW package is built open on a fabricated steel base frame with anti-vibration mounts, which keeps inspection, filter changes and fault finding straightforward.
Open frame diesel generators are robust and versatile power solutions widely used in various industries. These generators feature a sturdy frame structure that provides excellent protection and support for the internal components. With their powerful diesel engines, they offer reliable and efficient power generation for both standby and prime applications. The open frame design allows for easy access to the engine and other parts, simplifying maintenance and servicing. These generators are commonly employed in construction sites, remote locations, and as backup power sources, ensuring uninterrupted electricity supply even in challenging environments.
|
100 kW
Prime power
|
|
110 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
100 kW prime / 110 kW standby — 125 kVA — built as a open frame set package for small commercial and light industrial.
The Outevo 100 kW Open Frame Diesel Generator Set is used for retail units and small offices, workshops and repair bays, guesthouses and small clinics, typically intermittent prime duty with frequent start-stop cycles. Loads are normally light single-unit distribution boards.
Every unit is assembled and load-tested on our own production line for the 100 kW class. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas generator sets since 2006 from a 20,000 m² manufacturing facility with a fully automatic line, and more than 2,000 sets have been delivered to over 100 countries.
Protection on the 100 kW set is IP23 or higher, upgradable for dusty, humid, rainy or high-temperature sites.

The 100 kW package is built open on a fabricated steel base frame with anti-vibration mounts, which keeps inspection, filter changes and fault finding straightforward.

Declared output is 100 kW prime and 110 kW standby (125 kVA) at 380/220 V, 50 Hz, 1500 rpm. Design duty is intermittent prime duty with frequent start-stop cycles with light single-unit distribution boards.

At 100 kW the diesel engine is selected from Cummins, Perkins, Weichai and Yuchai, then matched and aligned to the alternator before full-load testing in our own facility.

Closed-circuit water cooling with forced fan and a large water tank is specified for the 100 kW set, which stabilises temperature in high ambient and continuous load duty.

The 100 kW set carries sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher, with uprated protection available for severe sites.

ATS, remote monitoring module, cable winch and quick connectors can be specified on the 100 kW set; the control, protection and voltage settings are configured to the project specification.
Standard open frame set configuration at 100 kW prime / 110 kW standby (125 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiDiesel engines on the 100 kW set are selected from these Tier-1 platforms and matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 100 kW set, an optional automatic transfer switch for automatic standby start, plus an optional remote monitoring module. The control and protection scheme on the 100 kW set is set to your project specification. |
Build configurationThis model ships as an open frame setThis model ships as an open frame set. Silent, containerized and mobile configurations are available across the 10–3,750 kVA range under OEM/ODM terms. |
1. Retail unitsWhere retail units and small offices is the load, the 100 kW rating is normally specified at intermittent prime duty with frequent start-stop cycles. The load is usually single-phase and three-phase mixed, so the set is configured with a distribution board matched to the 100 kW rating. |
2. WorkshopsThe 100 kW open frame diesel generator set set suits workshops and repair bays. Duty on the 100 kW set is intermittent prime duty with frequent start-stop cycles. Motor starting is light, so a modest step-load margin is enough at 100 kW. |
3. GuesthousesGuesthouses and small clinics is a standard application for the 100 kW unit, which runs at intermittent prime duty with frequent start-stop cycles. Duty on the 100 kW set is intermittent, so fuel autonomy is sized around shift patterns rather than continuous run. |
4. Water pumpsThe 100 kW set is commonly applied to water pumps and irrigation at intermittent prime duty with frequent start-stop cycles. Ambient around the 100 kW set is often unshaded, so the radiator and enclosure are specified for high daytime temperature. |
5. Small cold roomsFor small cold rooms the 100 kW rating covers small commercial and light industrial at intermittent prime duty with frequent start-stop cycles. Noise is a factor on residential sites, so canopy options are considered at the 100 kW rating. |
6. Construction hoistsWhere construction hoists and small tools is the load, the 100 kW rating is normally specified at intermittent prime duty with frequent start-stop cycles. Access to the 100 kW skid is usually tight, so the skid footprint and lifting points matter as much as output. |
The same engineering and testing standard applies to this 100 kW rating in all three builds — the difference is enclosure, access and transport.
| This model · 100 kW open frame diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All open frame sets |
Send us the required power for the 100 kW set, voltage and frequency and we will return a configuration.
Tell us the rating, voltage and frequency you need for the 100 kW unit and where it is going. Our engineering team returns a configuration and quotation.
Our representative will contact you soon.