L
O
A
D
I
N
G

Get a Free Quote

Our representative will contact you soon.
Name
Email
Company Name
Country
Mobile/WhatsApp
Required Power
Application
Project Details
0/1000

1200kW Containerized Diesel Generator Set Integrated Mobile Power Station for Industrial Project Emergency Power

Container type silent generator set is designed to deliver reliable power with low noise, high efficiency, and strong durability. Built with a modular containerized structure, it integrates advanced soundproofing technology, ventilation optimization, and anti-vibration design to ensure stable operation even under harsh working environments. With a power range of1000kw-2500kw, this generator is suitable for continuous and emergency applications, providing dependable performance for industrial, commercial, and large-scale projects.

Brand:
Outevo
  • Overview
  • Recommended Products
Containerized Diesel Generator Set · 1200 kW Prime / 1320 kW Standby

1200 kW Containerized Diesel Generator Set for Sites Without a Reliable Grid

One platform, four build types — open frame, silent canopy, containerized or trailer-mounted — configured to your site, your fuel and your duty. Tell us the load and the site, and we will confirm the build type, rating and lead time.

1200 kWPrime power1320 kWStandby power380/220 VRated voltage50 HzRated frequency1500 rpmRated speedIP23Protection grade
Manufacturing since 20062,000+ sets delivered100+ countriesLoad-tested before shipment
1200 kW
Prime power
1320 kW
Standby power
380/220 V
Rated voltage
2006+
Manufacturer since
Product overview

Heavy-duty containerized diesel generator sets for sites without a reliable grid

Rated 1200 kW prime and 1320 kW standby at 1500 kVA, supplied as a 40HQ container package unit for heavy industrial and project power.

Where it is installed — district cooling and chiller plants, hospitals and institutional campuses, oil and gas field facilities — the 1200 kW set works at continuous prime duty at high load factor. Distribution for the 1200 kW set is usually through main switchboards with motor-starting and step-load duty.

Each 1200 kW set is assembled and load-tested in our own works. Outevo has produced diesel and gas sets including this 1200 kW rating generating sets since 2006 from a 20,000 m² production base in Shandong with a fully automatic line, and has delivered more than 2,000 sets to over 100 countries.

IP23 or higher protection is standard on the 1200 kW set, with higher grades available for dust, humidity, rain or heat.

  • 1200 kW prime / 1320 kW standby at 380/220 V, 50 Hz, 1500 rpm
  • Full service access — service through container doors and reserved access panels
  • Tier-1 diesel engine platforms — Cummins, Perkins, Weichai and Yuchai
  • Closed water-cooling with forced fan and large-capacity water tank
  • IP23 or higher, upgradable for dust, humidity, rain and heat
Product features

Engineered for site conditions, not for the showroom

Heavy-Duty Container Construction

Heavy-Duty Container Construction

Engine, alternator and control panel are mounted on a steel base within a 40HQ container, making the 1200 kW station a single seaworthy package. Filters, belts and terminals stay reachable through the doors.

1200 kW Prime / 1320 kW Standby Duty

1200 kW Prime / 1320 kW Standby Duty

The 1200 kW prime / 1320 kW standby rating is declared at 380/220 V, 50 Hz, 1500 rpm (1500 kVA), intended for continuous prime duty at high load factor across main switchboards with motor-starting and step-load duty.

Tier-1 Diesel Engine Platforms

Tier-1 Diesel Engine Platforms

Engine options for the 1200 kW diesel set are Cummins, Perkins, Weichai and Yuchai; whichever is specified, the engine is matched to the alternator and load-tested in our own works.

Closed Water-Cooling with Forced Fan

Closed Water-Cooling with Forced Fan

The 1200 kW package uses closed water-cooling with forced ventilation and a large-capacity tank, holding temperatures steady during extended continuous duty in hot climates.

Industrial Protection and Environmental Adaptability

Industrial Protection and Environmental Adaptability

Enclosure sealing and anti-corrosion finishing are rated IP23 or higher on the 1200 kW set, upgradable for harsher sites, treating dust, rain, snow and temperature extremes as normal conditions.

Flexible Configuration and Fast Deployment

Flexible Configuration and Fast Deployment

Options on the 1200 kW set include an automatic transfer switch, remote monitoring, cable winch and quick connectors; base-frame arrangement and control, protection and voltage settings are set to the project specification.

Specifications

Technical data — 1200 kW containerized diesel generator set diesel generator set

Standard 40HQ container package configuration at 1200 kW prime / 1320 kW standby (1500 kVA). Ratings, voltage and frequency are confirmed at specification.

Related parameters Parameter values
Power Capacity Prime Power: 1200 kW   Standby Power: 1320 kW
Rated Voltage 380/220 Volts
Rated Current Issued with the approved data sheet for the selected build
Rated Frequency 50 Hertz
Rated Speed 1500 rpm
Fuel Type Diesel
Protection Grade IP23 or higherUpgradable upon customization

Published for the standard 40HQ container package configuration at 1200 kW prime (1500 kVA); the approved drawing and data sheet for your build govern installation design.

Engine & options

Specify the engine platform, control scheme and build

Engine platform

Cummins · Perkins · Weichai · Yuchai

For the 1200 kW set the engine is drawn from these Tier-1 platforms and matched to the alternator, with the final platform fixed at order stage.

Control & protection

ATS & remote monitoring

An automatic transfer switch and remote monitoring module can be specified on the 1200 kW set. The control and protection scheme on the 1200 kW set is configured to the project specification.

Build configuration

Containerized standard

Containerized standard

Applications

Where this 1200 kW containerized diesel generator set is used

1. Process plants

Process plants and heavy machinery is a standard application for the 1200 kW unit, which runs at continuous prime duty at high load factor. High load factor means the 1200 kW rating is checked against continuous duty rather than peak only.

2. Mining

The 1200 kW set is commonly applied to mining and aggregate sites at continuous prime duty at high load factor. Large motor starts and step loads drive the alternator sizing at 1200 kW.

3. District cooling

For district cooling and chiller plants the 1200 kW rating covers heavy industrial and project power at continuous prime duty at high load factor. Parallel operation and load sharing on the 1200 kW set are normally specified where redundancy is required.

4. Hospitals

Where hospitals and institutional campuses is the load, the 1200 kW rating is normally specified at continuous prime duty at high load factor. Main switchboard interface for the 1200 kW set and protection coordination are reviewed with the site electrical design.

5. Oil

The 1200 kW containerized diesel generator set set suits oil and gas field facilities. Duty is continuous prime duty at high load factor. Fuel storage and day-tank arrangement for the 1200 kW set are confirmed against the project fire and safety scheme.

6. Large construction packages

Large construction packages is a standard application for the 1200 kW unit, which runs at continuous prime duty at high load factor. Ambient and altitude derating for the 1200 kW set are applied where the site sits above sea-level design conditions.

Compare configurations

Open frame, silent or containerized?

This 1200 kW rating is engineered and tested to one standard across the three builds — what changes is enclosure, access and transport.

Consideration Containerized (this model) Silent Containerized
Enclosure Open steel base frame, no canopy Soundproof canopy 40HQ container shell
Service access Unrestricted — no panels to remove for routine maintenance Through canopy access doors and monitoring windows Through container doors and reserved access panels
Noise control Not attenuated — containerized layout Multi-stage silencing structure and sound-absorbing materials Container shell combined with silencing
Weight and transport Lightest of the three builds Heavier than containerized Container handling and ocean freight
Typical duty Prime power on site; standby for factories and buildings Noise-sensitive locations such as residential, commercial and healthcare sites Rapid transport and deployment, remote and long-duration sites
Rated power of this model 1200 kW prime / 1320 kW standby Quoted per project Quoted per project
Protection grade IP23 or higher, upgradable Upgradable upon customization Upgradable upon customization
Minimum order quantity 1 set Quoted per project Quoted per project
This model · 1200 kW containerized diesel generator set
Range · 10–3,750 kVA
Diesel & gas
Open frame · silent · containerized · mobile
All containerized sets

Tell us the rating, voltage and frequency for the 1200 kW unit and we will confirm a configuration.

FAQ

Frequently asked questions about this 1200 kW containerized diesel generator set

What power rating does this generator set provide?
This unit is rated 1200 kW prime / 1320 kW standby (1500 kVA) at 380/220 V, 50 Hz, 1500 rpm. Rated current is stated on the approved data sheet for the selected build, because it follows the voltage and power factor confirmed for the project.
Which diesel engines are available for this set?
This 1200 kW set is available on Cummins, Perkins, Weichai and Yuchai platforms. The engine is matched to the alternator at the 1200 kW rating and the complete set is aligned and full-load tested in our own works, so the platform for your order is confirmed at specification stage rather than assumed.
Containerized, silent or containerized — how do I choose?
Enclosure choice follows site conditions rather than rating. This page covers the 40HQ container package build; at 1200 kW the same engine and alternator package can also be supplied in the other builds across Outevo’s 10–3,750 kVA range, with parallel operation and load sharing can be specified.
Can the voltage and frequency be customised?
Yes. 380/220 V and 50 Hz are the published standard for the 1200 kW rating, but voltage and frequency are set to your project specification under OEM/ODM terms, including 60 Hz and medium-voltage requirements where the project calls for them.
What is the minimum order quantity?
One set. A single 1200 kW unit can be ordered for a standalone site; where load growth or redundancy is expected, parallel operation and load sharing can be specified. Other ratings in the 10–3,750 kVA range are quoted per project.
How is the quality of each unit assured?
Every 1200 kW set is assembled and load-tested on our own production lines before shipment, and travels with a data sheet and test record. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas sets including this 1200 kW rating generator sets since 2006 from a 20,000 m² production base in Shandong.
Get a quote

Configure your 1200 kW containerized diesel generator set diesel generator set

Send the voltage and frequency you need with the 1200 kW rating and the site location, and our engineering team returns a configuration and quotation.

What we need from you

  • Required power rating — this model or another rating in the 10–3,750 kVA range
  • Voltage and frequency settings for your site
  • Prime power or standby duty, and the application
  • Destination port and required quantity

Request a quote

Our representative will contact you soon.

Your configuration: 1200 kW containerized diesel generator set (this model), 380/220 V, 50 Hz

Custom and OEM/ODM configurations are quoted project by project.

2006+
Manufacturing since
100+
Countries served
2,000+
Sets delivered
20,000 m²
Production base



Email: [email protected]

Phone: +86-13280035385

Get a Free Quote

Our representative will contact you soon.
Name
Email
Company Name
Country
Mobile/WhatsApp
Required Power
Application
Project Details
0/1000