Heavy-Duty Natural Gas Construction
The 1200 kW package is delivered assembled on its base frame, so installation inside or beside the production building is limited to positioning, fuel connection and cabling.
The silent gas generator set is specially designed to deliver clean low-carbon, quiet stable, efficient and durable power supply. Adopting an integrated compact structure, it integrates professional sound insulation and noise reduction technology, intelligent ventilation and heat dissipation system, and multi-stage anti-vibration buffer design, balancing environmental friendliness, reliability and operation and maintenance convenience.
|
1200 kW
Prime power
|
|
1320 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
One natural gas package package, 1200 kW prime and 1320 kW standby (1500 kVA), aimed at heavy industrial and project power.
This 1200 kW Natural Gas Generator Set is specified for mining and aggregate sites, district cooling and chiller plants, hospitals and institutional campuses. Typical duty for the 1200 kW set is continuous prime duty at high load factor, feeding main switchboards with motor-starting and step-load duty.
Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 1200 kW class generator sets since 2006 at a 20,000 m² manufacturing facility served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.
The 1200 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

The 1200 kW package is delivered assembled on its base frame, so installation inside or beside the production building is limited to positioning, fuel connection and cabling.

Design duty at 1200 kW prime and 1320 kW standby is continuous running through the working day, which is why the alternator and cooling system are sized for sustained load rather than short standby duty.

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms and matched to the alternator before full-load testing on our own production line.

Closed-circuit water cooling with forced fan and a large water tank is specified because a plant set runs for whole shifts and cannot rely on short cooling recovery periods.

Sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher, uprated for foundry dust, humid areas or high ambient workshops.

ATS, remote monitoring, cable winch and quick connectors can be specified so the set can be redeployed between bays or buildings as the plant layout changes.
Standard natural gas package configuration at 1200 kW prime / 1320 kW standby (1500 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiEngines on the 1200 kW set are selected from the Cummins, Perkins, Weichai and Yuchai platforms and matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 1200 kW set an optional automatic transfer switch and remote monitoring module are available, with protection settings configured for continuous prime duty. |
Build configurationThis model ships as a natural gas package set, normally in a soundproof canopyThis model ships as a silent set. Open frame, containerized and mobile builds of the same rating are available under OEM/ODM terms. |
1. Production lines and machine toolsCarries the whole working-day load of the plant where the grid supply is either absent or too weak to run the line. |
2. Compressors and process pumpsTakes the starting current of large motors and keeps process pumps running without an operator restarting them after each trip. |
3. Furnaces, dryers and ovensHolds process temperature through a shift, which is what prevents scrap and rework when the supply is unstable. |
4. Cold storage and process coolingKeeps refrigeration and cooling loops live, protecting product that would otherwise be lost in a long outage. |
5. Workshop and maintenance baysRuns welding, lifting and compressed-air equipment in the maintenance area independent of the main supply. |
6. Shift-pattern continuous demandSuits plants that work two or three shifts, where the set is the primary source and fuel and service planning follows production hours. |
Whichever build is chosen for the 1200 kW rating, engineering and testing are identical; only the enclosure, access and transport change.
| This model · 1200 kW natural gas generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All natural gas sets |
Give us the power for the 1200 kW set, voltage and frequency and we will come back with a configuration.
Give us the voltage and frequency for the 1200 kW set and the destination site; our engineering team comes back with a configuration and quotation.