Heavy-Duty Silent Construction
A soundproof canopy encloses the 70 kW package, itself mounted on a fabricated base with anti-vibration isolators. Service points stay reachable without separating the set.
Silent generator sets are designed to deliver stable power output with ultra-low noise levels, making them the ideal choice for residential, commercial, and industrial applications. With advanced soundproof technology, durable steel enclosures, and high-efficiency engines, our generator sets provide reliable electricity while minimizing environmental impact.
|
70 kW
Prime power
|
|
77 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
Rated 70 kW prime and 77 kW standby at 88 kVA, supplied as a soundproof canopy set unit for small commercial and light industrial.
Where it is installed — guesthouses and small clinics, water pumps and irrigation, small cold rooms — the 70 kW set works at intermittent prime duty with frequent start-stop cycles. Distribution for the 70 kW set is usually through light single-unit distribution boards.
Each 70 kW set is assembled and load-tested in our own works. Outevo has produced diesel and gas sets including this 70 kW rating generating sets since 2006 from a 20,000 m² manufacturing facility with a fully automatic line, and has delivered more than 2,000 sets to over 100 countries.
IP23 or higher protection is standard on the 70 kW set, with higher grades available for dust, humidity, rain or heat.

A soundproof canopy encloses the 70 kW package, itself mounted on a fabricated base with anti-vibration isolators. Service points stay reachable without separating the set.

The 70 kW prime / 77 kW standby rating is declared at 380/220 V, 50 Hz, 1500 rpm (88 kVA), intended for intermittent prime duty with frequent start-stop cycles across light single-unit distribution boards.

Engine options for the 70 kW diesel set are Cummins, Perkins, Weichai and Yuchai; whichever is specified, the engine is matched to the alternator and load-tested in our own works.

The 70 kW package uses closed water-cooling with forced ventilation and a large-capacity tank, holding temperatures steady during extended continuous duty in hot climates.

Enclosure sealing and anti-corrosion finishing are rated IP23 or higher on the 70 kW set, upgradable for harsher sites, treating dust, rain, snow and temperature extremes as normal conditions.

Options on the 70 kW set include an automatic transfer switch, remote monitoring, cable winch and quick connectors; base-frame arrangement and control, protection and voltage settings are set to the project specification.
Standard soundproof canopy set configuration at 70 kW prime / 77 kW standby (88 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiFor the 70 kW set the engine is drawn from these Tier-1 platforms and matched to the alternator, with the final platform fixed at order stage. |
Control & protectionATS & remote monitoringAn automatic transfer switch and remote monitoring module can be specified on the 70 kW set. The control and protection scheme on the 70 kW set is configured to the project specification. |
Build configurationSilent canopy standardSilent canopy standard |
1. Retail unitsRetail units and small offices is a standard application for the 70 kW unit, which runs at intermittent prime duty with frequent start-stop cycles. The load is usually single-phase and three-phase mixed, so the set is configured with a distribution board matched to the 70 kW rating. |
2. WorkshopsThe 70 kW set is commonly applied to workshops and repair bays at intermittent prime duty with frequent start-stop cycles. Motor starting is light, so a modest step-load margin is enough at 70 kW. |
3. GuesthousesFor guesthouses and small clinics the 70 kW rating covers small commercial and light industrial at intermittent prime duty with frequent start-stop cycles. Duty on the 70 kW set is intermittent, so fuel autonomy is sized around shift patterns rather than continuous run. |
4. Water pumpsWhere water pumps and irrigation is the load, the 70 kW rating is normally specified at intermittent prime duty with frequent start-stop cycles. Ambient around the 70 kW set is often unshaded, so the radiator and enclosure are specified for high daytime temperature. |
5. Small cold roomsThe 70 kW silent diesel generator set set suits small cold rooms. Duty on the 70 kW set is intermittent prime duty with frequent start-stop cycles. Noise is a factor on residential sites, so canopy options are considered at the 70 kW rating. |
6. Construction hoistsConstruction hoists and small tools is a standard application for the 70 kW unit, which runs at intermittent prime duty with frequent start-stop cycles. Access to the 70 kW skid is usually tight, so the skid footprint and lifting points matter as much as output. |
This 70 kW rating is engineered and tested to one standard across the three builds — what changes is enclosure, access and transport.
| This model · 70 kW silent diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All silent sets |
Tell us the rating, voltage and frequency for the 70 kW unit and we will confirm a configuration.
Send the voltage and frequency you need with the 70 kW rating and the site location, and our engineering team returns a configuration and quotation.