Heavy-Duty Container Construction
For the 1040 kW rating the enclosure is a 40HQ container with the engine, alternator and control system mounted on an internal base, giving weatherproof transport and service access through doors and hatches.
Container type silent generator set is designed to deliver reliable power with low noise, high efficiency, and strong durability. Built with a modular containerized structure, it integrates advanced soundproofing technology, ventilation optimization, and anti-vibration design to ensure stable operation even under harsh working environments. With a power range of1000kw-2500kw, this generator is suitable for continuous and emergency applications, providing dependable performance for industrial, commercial, and large-scale projects.
|
1040 kW
Prime power
|
|
1144 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
One 40HQ container package package, 1040 kW prime and 1144 kW standby (1300 kVA), aimed at heavy industrial and project power.
This 1040 kW Containerized Diesel Generator Set is specified for mining and aggregate sites, district cooling and chiller plants, hospitals and institutional campuses. Typical duty for the 1040 kW set is continuous prime duty at high load factor, feeding main switchboards with motor-starting and step-load duty.
Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 1040 kW class generator sets since 2006 at a 20,000 m² Shandong base served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.
The 1040 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

For the 1040 kW rating the enclosure is a 40HQ container with the engine, alternator and control system mounted on an internal base, giving weatherproof transport and service access through doors and hatches.

At 380/220 V, 50 Hz and 1500 rpm the set delivers 1040 kW prime / 1144 kW standby, 1300 kVA. It is specified for continuous prime duty at high load factor.

Diesel engine platform choices for this 1040 kW set are Cummins, Perkins, Weichai and Yuchai; the platform for your order is confirmed at order stage after alternator matching.

For the 1040 kW rating, cooling is closed water-circuit with forced ventilation; the oversized tank absorbs heat soak during long continuous operation.

Protection on the 1040 kW unit is IP23 or higher by sealing and anti-corrosion finishing, upgradable where dust, rain, snow or heat are more severe.

Site wiring and start-up on the 1040 kW set can be shortened with an optional ATS, remote monitoring, cable winch and quick connectors; the remaining settings follow the project specification.
Standard 40HQ container package configuration at 1040 kW prime / 1144 kW standby (1300 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiThe 1040 kW rating can be built on any of these Tier-1 platforms, each matched to the alternator; the platform is confirmed when the order is placed. |
Control & protectionATS & remote monitoringFor the 1040 kW set, ATS for automatic standby starting and an optional remote monitoring module are available. Control and protection logic follows the project specification. |
Build configurationContainerized standardContainerized standard |
1. Process plantsThe 1040 kW set is commonly applied to process plants and heavy machinery at continuous prime duty at high load factor. High load factor means the 1040 kW rating is checked against continuous duty rather than peak only. |
2. MiningFor mining and aggregate sites the 1040 kW rating covers heavy industrial and project power at continuous prime duty at high load factor. Large motor starts and step loads drive the alternator sizing at 1040 kW. |
3. District coolingWhere district cooling and chiller plants is the load, the 1040 kW rating is normally specified at continuous prime duty at high load factor. Parallel operation and load sharing on the 1040 kW set are normally specified where redundancy is required. |
4. HospitalsThe 1040 kW containerized diesel generator set set suits hospitals and institutional campuses. Duty is continuous prime duty at high load factor. Main switchboard interface for the 1040 kW set and protection coordination are reviewed with the site electrical design. |
5. OilOil and gas field facilities is a standard application for the 1040 kW unit, which runs at continuous prime duty at high load factor. Fuel storage and day-tank arrangement for the 1040 kW set are confirmed against the project fire and safety scheme. |
6. Large construction packagesThe 1040 kW set is commonly applied to large construction packages at continuous prime duty at high load factor. Ambient and altitude derating for the 1040 kW set are applied where the site sits above sea-level design conditions. |
Whichever build is chosen for the 1040 kW rating, engineering and testing are identical; only the enclosure, access and transport change.
| This model · 1040 kW containerized diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All containerized sets |
Give us the power for the 1040 kW set, voltage and frequency and we will come back with a configuration.
Give us the voltage and frequency for the 1040 kW set and the destination site; our engineering team comes back with a configuration and quotation.
Our representative will contact you soon.