Heavy-Duty Biogas Construction
Engine, alternator and control panel for the 1000 kW gas unit sit on a fabricated base, with the gas train pressure-tested and the package wired before dispatch.
The silent gas generator set is specially designed to deliver clean low-carbon, quiet stable, efficient and durable power supply. Adopting an integrated compact structure, it integrates professional sound insulation and noise reduction technology, intelligent ventilation and heat dissipation system, and multi-stage anti-vibration buffer design, balancing environmental friendliness, reliability and operation and maintenance convenience.
|
1000 kW
Prime power
|
|
1100 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
One biogas package package, 1000 kW prime and 1100 kW standby (1250 kVA), aimed at heavy industrial and project power.
This 1000 kW Biogas Generator Set is specified for mining and aggregate sites, district cooling and chiller plants, hospitals and institutional campuses. Typical duty for the 1000 kW set is continuous prime duty at high load factor, feeding main switchboards with motor-starting and step-load duty.
Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 1000 kW class generator sets since 2006 at a 20,000 m² Shandong base served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.
The 1000 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

Engine, alternator and control panel for the 1000 kW gas unit sit on a fabricated base, with the gas train pressure-tested and the package wired before dispatch.

At 380/220 V, 50 Hz and 1500 rpm the set delivers 1000 kW prime / 1100 kW standby, 1250 kVA. It is specified for continuous prime duty at high load factor.

Gas engine platform choices for this 1000 kW set are Cummins and Weichai; the platform for your order is confirmed at order stage after alternator matching.

For the 1000 kW rating, cooling is closed water-circuit with forced ventilation; the oversized tank absorbs heat soak during long continuous operation.

Protection on the 1000 kW unit is IP23 or higher by sealing and anti-corrosion finishing, upgradable where dust, rain, snow or heat are more severe.

Site wiring and start-up on the 1000 kW set can be shortened with an optional ATS, remote monitoring, cable winch and quick connectors; the remaining settings follow the project specification.
Standard biogas package configuration at 1000 kW prime / 1100 kW standby (1250 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiThe 1000 kW rating can be built on any of these Tier-1 platforms, each matched to the alternator; the platform is confirmed when the order is placed. |
Control & protectionATS & remote monitoringFor the 1000 kW set, ATS for automatic standby starting and an optional remote monitoring module are available. Control and protection logic follows the project specification. |
Build configurationBiogas standardBiogas standard |
1. Process plantsThe 1000 kW set is commonly applied to process plants and heavy machinery at continuous prime duty at high load factor. High load factor means the 1000 kW rating is checked against continuous duty rather than peak only. |
2. MiningFor mining and aggregate sites the 1000 kW rating covers heavy industrial and project power at continuous prime duty at high load factor. Large motor starts and step loads drive the alternator sizing at 1000 kW. |
3. District coolingWhere district cooling and chiller plants is the load, the 1000 kW rating is normally specified at continuous prime duty at high load factor. Parallel operation and load sharing on the 1000 kW set are normally specified where redundancy is required. |
4. HospitalsThe 1000 kW biogas generator set set suits hospitals and institutional campuses. Duty is continuous prime duty at high load factor. Main switchboard interface for the 1000 kW set and protection coordination are reviewed with the site electrical design. |
5. OilOil and gas field facilities is a standard application for the 1000 kW unit, which runs at continuous prime duty at high load factor. Fuel storage and day-tank arrangement for the 1000 kW set are confirmed against the project fire and safety scheme. |
6. Large construction packagesThe 1000 kW set is commonly applied to large construction packages at continuous prime duty at high load factor. Ambient and altitude derating for the 1000 kW set are applied where the site sits above sea-level design conditions. |
Whichever build is chosen for the 1000 kW rating, engineering and testing are identical; only the enclosure, access and transport change.
| This model · 1000 kW biogas generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All biogas sets |
Give us the power for the 1000 kW set, voltage and frequency and we will come back with a configuration.
Give us the voltage and frequency for the 1000 kW set and the destination site; our engineering team comes back with a configuration and quotation.
Our representative will contact you soon.