Heavy-Duty Natural Gas Construction
Engine, alternator and control panel for the 500 kW gas unit sit on a fabricated base, with the gas train pressure-tested and the package wired before dispatch.
The natural gas generator set is specially designed to deliver clean low-carbon, quiet stable, efficient and durable power supply. Adopting an integrated compact structure, it integrates professional sound insulation and noise reduction technology, intelligent ventilation and heat dissipation system, and multi-stage anti-vibration buffer design, balancing environmental friendliness, reliability and operation and maintenance convenience.
|
500 kW
Prime power
|
|
550 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
One natural gas package package, 500 kW prime and 550 kW standby (625 kVA), aimed at mid-size industrial and site power.
This 500 kW Natural Gas Generator Set is specified for hotels and commercial buildings, data and telecom rooms, quarries and crushing plants. Typical duty for the 500 kW set is continuous prime duty with regular load swings, feeding panel boards with mixed motor and lighting loads.
Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 500 kW class generator sets since 2006 at a 20,000 m² Shandong base served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.
The 500 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

Engine, alternator and control panel for the 500 kW gas unit sit on a fabricated base, with the gas train pressure-tested and the package wired before dispatch.

At 380/220 V, 50 Hz and 1500 rpm the set delivers 500 kW prime / 550 kW standby, 625 kVA. It is specified for continuous prime duty with regular load swings.

Gas engine platform choices for this 500 kW set are Cummins and Weichai; the platform for your order is confirmed at order stage after alternator matching.

For the 500 kW rating, cooling is closed water-circuit with forced ventilation; the oversized tank absorbs heat soak during long continuous operation.

Protection on the 500 kW unit is IP23 or higher by sealing and anti-corrosion finishing, upgradable where dust, rain, snow or heat are more severe.

Site wiring and start-up on the 500 kW set can be shortened with an optional ATS, remote monitoring, cable winch and quick connectors; the remaining settings follow the project specification.
Standard natural gas package configuration at 500 kW prime / 550 kW standby (625 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiThe 500 kW rating can be built on any of these Tier-1 platforms, each matched to the alternator; the platform is confirmed when the order is placed. |
Control & protectionATS & remote monitoringFor the 500 kW set, ATS for automatic standby starting and an optional remote monitoring module are available. Control and protection logic follows the project specification. |
Build configurationNatural Gas standardNatural Gas standard |
1. Production linesThe 500 kW set is commonly applied to production lines and compressors at continuous prime duty with regular load swings. Mixed motor and lighting load means the alternator is matched with step-load margin at 500 kW. |
2. HotelsFor hotels and commercial buildings the 500 kW rating covers mid-size industrial and site power at continuous prime duty with regular load swings. Shift patterns for the 500 kW set usually mean 12–16 hours a day, so fuel autonomy is calculated on that basis. |
3. DataWhere data and telecom rooms is the load, the 500 kW rating is normally specified at continuous prime duty with regular load swings. Compressor and motor starts drive the transient requirement, which is checked against the 500 kW rating. |
4. QuarriesThe 500 kW natural gas generator set set suits quarries and crushing plants. Duty is continuous prime duty with regular load swings. Parallel operation on the 500 kW set is often considered where duty is split between two units. |
5. Agricultural processingAgricultural processing is a standard application for the 500 kW unit, which runs at continuous prime duty with regular load swings. Sound limits at the boundary usually point to a canopy build at the 500 kW rating. |
6. Site officesThe 500 kW set is commonly applied to site offices and welfare blocks at continuous prime duty with regular load swings. Cable runs for the 500 kW set are longer, so voltage drop is checked before the final rating is fixed. |
Whichever build is chosen for the 500 kW rating, engineering and testing are identical; only the enclosure, access and transport change.
| This model · 500 kW natural gas generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All natural gas sets |
Give us the power for the 500 kW set, voltage and frequency and we will come back with a configuration.
Give us the voltage and frequency for the 500 kW set and the destination site; our engineering team comes back with a configuration and quotation.
Our representative will contact you soon.