Heavy-Duty Container Construction
The 1200 kW package arrives as one unit with the enclosure, base frame and control panel already assembled, so installation work on site is limited to positioning, cabling and commissioning.
Container type silent generator set is designed to deliver reliable power with low noise, high efficiency, and strong durability. Built with a modular containerized structure, it integrates advanced soundproofing technology, ventilation optimization, and anti-vibration design to ensure stable operation even under harsh working environments. With a power range of1000kw-2500kw, this generator is suitable for continuous and emergency applications, providing dependable performance for industrial, commercial, and large-scale projects.
|
1200 kW
Prime power
|
|
1320 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
1200 kW prime / 1320 kW standby — 1500 kVA — built as a 40HQ container package package for heavy industrial and project power.
A data centre cannot accept an outage in the middle of a transaction. This 1200 kW containerized set (1,500 kVA prime, 1320 kW standby) is specified as the standby source for IT and mechanical loads. Standby duty in a data centre means long idle periods interrupted by a hard step load. The KTA50-GS8 engine is matched to the 1200 kW rating with a closed water-cooling circuit, and every unit is assembled and load-tested on Outevo production lines.
Every unit is assembled and load-tested on our own production line for the 1200 kW class. The containerized build is lined with sound-absorbing material so the set can sit close to a technical building without breaching site noise limits. ATS, remote monitoring and paralleling schemes are configured to the specification. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas generator sets since 2006 from a 20,000 m² manufacturing facility, and more than 2,000 sets have been delivered to over 100 countries.
Protection on the 1200 kW set is IP23 or higher, upgradable for dusty, humid, rainy or high-temperature sites.

The 1200 kW package arrives as one unit with the enclosure, base frame and control panel already assembled, so installation work on site is limited to positioning, cabling and commissioning.

Design duty at 1200 kW prime and 1320 kW standby is standby operation with a hard step load, which is why the alternator is matched against starting kVA rather than running kW alone.

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms and aligned to the alternator before full-load testing, which is the test that proves the step-load response.

Closed-circuit water cooling with forced fan and a large water tank keeps coolant temperature stable during long idle periods interrupted by sudden load, a pattern typical of data centre standby.

Sealed dustproof and anti-corrosion treatment to IP23 or higher, with fire-system and alarm interfaces available so the set integrates with the building life-safety scheme.

ATS, remote monitoring and synchronising options can be specified; where two or more units share the load, control and load-sharing settings are configured to the site scheme.
Standard 40HQ container package configuration at 1200 kW prime / 1320 kW standby (1500 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiEngines on the 1200 kW set come from the Cummins, Perkins, Weichai and Yuchai platforms and are matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 1200 kW set an optional automatic transfer switch and remote monitoring module are available, so the transition happens without an operator on site. |
Build configurationThis model ships as a 40HQ containerized setThis model ships as a containerized set. Open frame, containerized and mobile builds of the same rating are available under OEM/ODM terms. |
1. IT and UPS supportTakes over the critical bus when the utility fails, carrying servers, storage and network equipment through an outage of any duration. |
2. Cooling and chilled-water plantDrives chillers, pumps and CRAC units so heat rejection continues after the mains drops, which is what actually protects the IT load. |
3. Automatic transfer and parallelingStarted through an optional ATS or a synchronising panel so the transition happens without an operator on site. |
4. Edge and container sitesSized for remote edge nodes where the incoming supply is one feed only and the generator is the sole backup. |
5. Maintenance and load-bank testingSupports scheduled testing with resistive load banks so the set is proven at rated load rather than idled. |
6. Fire, access and security systemsKeeps fire suppression, access control and CCTV live during an outage, including the period before the mains returns. |
The same engineering and testing standard applies to this 1200 kW rating in all three builds — the difference is enclosure, access and transport.
| This model · 1200 kW containerized diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All containerized sets |
Send us the required power for the 1200 kW set, voltage and frequency and we will return a configuration.
Tell us the rating, voltage and frequency you need for the 1200 kW unit and where it is going. Our engineering team returns a configuration and quotation.
Our representative will contact you soon.