L
O
A
D
I
N
G

Get a Free Quote

Our representative will contact you soon.
Name
Email
Company Name
Country
Mobile/WhatsApp
Required Power
Application
Project Details
0/1000

Professional Open Frame Power Generator Set 450kW Prime & Standby Power For Factory Hotel Construction With Smart ECU

Open frame diesel generators are robust and versatile power solutions widely used in various industries. These generators feature a sturdy frame structure that provides excellent protection and support for the internal components. With their powerful diesel engines, they offer reliable and efficient power generation for both standby and prime applications. The open frame design allows for easy access to the engine and other parts, simplifying maintenance and servicing. These generators are commonly employed in construction sites, remote locations, and as backup power sources, ensuring uninterrupted electricity supply even in challenging environments.

Brand:
Outevo
  • Overview
  • Recommended Products
Open Frame Diesel Generator Set · 450 kW Prime / 495 kW Standby

450 kW Open Frame Diesel Generator Set for Sites Without a Reliable Grid

One platform, four build types — open frame, silent canopy, containerized or trailer-mounted — configured to your site, your fuel and your duty. Tell us the load and the site, and we will confirm the build type, rating and lead time.

450 kWPrime power495 kWStandby power380/220 VRated voltage50 HzRated frequency1500 rpmRated speedIP23Protection grade
Manufacturing since 20062,000+ sets delivered100+ countriesLoad-tested before shipment
450 kW
Prime power
495 kW
Standby power
380/220 V
Rated voltage
2006+
Manufacturer since
Product overview

Heavy-duty open frame diesel generator sets for sites without a reliable grid

Rated 450 kW prime and 495 kW standby at 562 kVA, supplied as a open frame set unit for mid-size industrial and site power.

Where it is installed — data and telecom rooms, quarries and crushing plants, agricultural processing — the 450 kW set works at continuous prime duty with regular load swings. Distribution for the 450 kW set is usually through panel boards with mixed motor and lighting loads.

Each 450 kW set is assembled and load-tested in our own works. Outevo has produced diesel and gas sets including this 450 kW rating generating sets since 2006 from a 20,000 m² production base in Shandong with a fully automatic line, and has delivered more than 2,000 sets to over 100 countries.

IP23 or higher protection is standard on the 450 kW set, with higher grades available for dust, humidity, rain or heat.

  • 450 kW prime / 495 kW standby at 380/220 V, 50 Hz, 1500 rpm
  • Full service access — no panels to remove for routine maintenance
  • Tier-1 diesel engine platforms — Cummins, Perkins, Weichai and Yuchai
  • Closed water-cooling with forced fan and large-capacity water tank
  • IP23 or higher, upgradable for dust, humidity, rain and heat
Product features

Engineered for site conditions, not for the showroom

Heavy-Duty Open Frame Construction

Heavy-Duty Open Frame Construction

A rigid fabricated steel base carries the engine, alternator and control system on anti-vibration mounts. Nothing is enclosed, so every service point stays open to the site.

450 kW Prime / 495 kW Standby Duty

450 kW Prime / 495 kW Standby Duty

The 450 kW prime / 495 kW standby rating is declared at 380/220 V, 50 Hz, 1500 rpm (562 kVA), intended for continuous prime duty with regular load swings across panel boards with mixed motor and lighting loads.

Tier-1 Diesel Engine Platforms

Tier-1 Diesel Engine Platforms

Engine options for the 450 kW diesel set are Cummins, Perkins, Weichai and Yuchai; whichever is specified, the engine is matched to the alternator and load-tested in our own works.

Closed Water-Cooling with Forced Fan

Closed Water-Cooling with Forced Fan

The 450 kW package uses closed water-cooling with forced ventilation and a large-capacity tank, holding temperatures steady during extended continuous duty in hot climates.

Industrial Protection and Environmental Adaptability

Industrial Protection and Environmental Adaptability

Enclosure sealing and anti-corrosion finishing are rated IP23 or higher on the 450 kW set, upgradable for harsher sites, treating dust, rain, snow and temperature extremes as normal conditions.

Flexible Configuration and Fast Deployment

Flexible Configuration and Fast Deployment

Options on the 450 kW set include an automatic transfer switch, remote monitoring, cable winch and quick connectors; base-frame arrangement and control, protection and voltage settings are set to the project specification.

Specifications

Technical data — 450 kW open frame diesel generator set

Standard open frame set configuration at 450 kW prime / 495 kW standby (562 kVA). Ratings, voltage and frequency are confirmed at specification.

Related parameters Parameter values
Power Capacity Prime Power: 450 kW   Standby Power: 495 kW
Rated Voltage 380/220 Volts
Rated Current Issued with the approved data sheet for the selected build
Rated Frequency 50 Hertz
Rated Speed 1500 rpm
Fuel Type Diesel
Protection Grade IP23 or higherUpgradable upon customization

Published for the standard open frame set configuration at 450 kW prime (562 kVA); the approved drawing and data sheet for your build govern installation design.

Engine & options

Specify the engine platform, control scheme and build

Engine platform

Cummins · Perkins · Weichai · Yuchai

For the 450 kW set the engine is drawn from these Tier-1 platforms and matched to the alternator, with the final platform fixed at order stage.

Control & protection

ATS & remote monitoring

An automatic transfer switch and remote monitoring module can be specified on the 450 kW set. The control and protection scheme on the 450 kW set is configured to the project specification.

Build configuration

Open frame standard

Open frame standard

Applications

Where this 450 kW open frame diesel generator set is used

1. Production lines

Production lines and compressors is a standard application for the 450 kW unit, which runs at continuous prime duty with regular load swings. Mixed motor and lighting load means the alternator is matched with step-load margin at 450 kW.

2. Hotels

The 450 kW set is commonly applied to hotels and commercial buildings at continuous prime duty with regular load swings. Shift patterns for the 450 kW set usually mean 12–16 hours a day, so fuel autonomy is calculated on that basis.

3. Data

For data and telecom rooms the 450 kW rating covers mid-size industrial and site power at continuous prime duty with regular load swings. Compressor and motor starts drive the transient requirement, which is checked against the 450 kW rating.

4. Quarries

Where quarries and crushing plants is the load, the 450 kW rating is normally specified at continuous prime duty with regular load swings. Parallel operation on the 450 kW set is often considered where duty is split between two units.

5. Agricultural processing

The 450 kW open frame diesel generator set set suits agricultural processing. Duty is continuous prime duty with regular load swings. Sound limits at the boundary usually point to a canopy build at the 450 kW rating.

6. Site offices

Site offices and welfare blocks is a standard application for the 450 kW unit, which runs at continuous prime duty with regular load swings. Cable runs for the 450 kW set are longer, so voltage drop is checked before the final rating is fixed.

Compare configurations

Open frame, silent or containerized?

This 450 kW rating is engineered and tested to one standard across the three builds — what changes is enclosure, access and transport.

Consideration Open frame (this model) Silent Containerized
Enclosure Open steel base frame, no canopy Soundproof canopy 40HQ container shell
Service access Unrestricted — no panels to remove for routine maintenance Through canopy access doors and monitoring windows Through container doors and reserved access panels
Noise control Not attenuated — open frame layout Multi-stage silencing structure and sound-absorbing materials Container shell combined with silencing
Weight and transport Lightest of the three builds Heavier than open frame Container handling and ocean freight
Typical duty Prime power on site; standby for factories and buildings Noise-sensitive locations such as residential, commercial and healthcare sites Rapid transport and deployment, remote and long-duration sites
Rated power of this model 450 kW prime / 495 kW standby Quoted per project Quoted per project
Protection grade IP23 or higher, upgradable Upgradable upon customization Upgradable upon customization
Minimum order quantity 1 set Quoted per project Quoted per project
This model · 450 kW open frame diesel generator set
Range · 10–3,750 kVA
Diesel & gas
Open frame · silent · containerized · mobile
All open frame sets

Tell us the rating, voltage and frequency for the 450 kW unit and we will confirm a configuration.

FAQ

Frequently asked questions about this 450 kW open frame diesel generator set

What power rating does this generator set provide?
This unit is rated 450 kW prime / 495 kW standby (562 kVA) at 380/220 V, 50 Hz, 1500 rpm. Rated current is stated on the approved data sheet for the selected build, because it follows the voltage and power factor confirmed for the project.
Which diesel engines are available for this set?
This 450 kW set is available on Cummins, Perkins, Weichai and Yuchai platforms. The engine is matched to the alternator at the 450 kW rating and the complete set is aligned and full-load tested in our own works, so the platform for your order is confirmed at specification stage rather than assumed.
Open Frame, silent or containerized — how do I choose?
Enclosure choice follows site conditions rather than rating. This page covers the open frame set build; at 450 kW the same engine and alternator package can also be supplied in the other builds across Outevo’s 10–3,750 kVA range, with parallel operation is available where duty is split across two units.
Can the voltage and frequency be customised?
Yes. 380/220 V and 50 Hz are the published standard for the 450 kW rating, but voltage and frequency are set to your project specification under OEM/ODM terms, including 60 Hz and medium-voltage requirements where the project calls for them.
What is the minimum order quantity?
One set. A single 450 kW unit can be ordered for a standalone site; where load growth or redundancy is expected, parallel operation is available where duty is split across two units. Other ratings in the 10–3,750 kVA range are quoted per project.
How is the quality of each unit assured?
Every 450 kW set is assembled and load-tested on our own production lines before shipment, and travels with a data sheet and test record. Shanghai Outevo Machinery Co., Ltd. has manufactured diesel and gas generator sets since 2006 from a 20,000 m² production base in Shandong.
Get a quote

Configure your 450 kW open frame diesel generator set

Send the voltage and frequency you need with the 450 kW rating and the site location, and our engineering team returns a configuration and quotation.

What we need from you

  • Required power rating — this model or another rating in the 10–3,750 kVA range
  • Voltage and frequency settings for your site
  • Prime power or standby duty, and the application
  • Destination port and required quantity

Request a quote

Our representative will contact you soon.

Your configuration: 450 kW open frame diesel generator set (this model), 380/220 V, 50 Hz

Custom and OEM/ODM configurations are quoted project by project.

2006+
Manufacturing since
100+
Countries served
2,000+
Sets delivered
20,000 m²
Production base



Email: [email protected]

Phone: +86-13280035385

Get a Free Quote

Our representative will contact you soon.
Name
Email
Company Name
Country
Mobile/WhatsApp
Required Power
Application
Project Details
0/1000