Heavy-Duty Trailer-Mounted Construction
Engine and alternator are bolted to a trailer chassis rated for road towing on anti-vibration mounts, so one tow moves the 300 kW unit between jobs.
-Model: Trailer Generator Set
-Speed: 1500 RPM
-Rated output: 33 KW
-Engine type: In-line, 4-stroke, water cooled
-Combustion type: Direct Injection
|
300 kW
Prime power
|
|
330 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
Rated 300 kW prime and 330 kW standby at 375 kVA, supplied as a road-towable trailer unit unit for mid-size industrial and site power.
Where it is installed — data and telecom rooms, quarries and crushing plants, agricultural processing — the 300 kW set works at continuous prime duty with regular load swings. Distribution for the 300 kW set is usually through panel boards with mixed motor and lighting loads.
Each 300 kW set is assembled and load-tested in our own works. Outevo has produced diesel and gas sets including this 300 kW rating generating sets since 2006 from a 20,000 m² manufacturing facility with a fully automatic line, and has delivered more than 2,000 sets to over 100 countries.
IP23 or higher protection is standard on the 300 kW set, with higher grades available for dust, humidity, rain or heat.

Engine and alternator are bolted to a trailer chassis rated for road towing on anti-vibration mounts, so one tow moves the 300 kW unit between jobs.

The 300 kW prime / 330 kW standby rating is declared at 380/220 V, 50 Hz, 1500 rpm (375 kVA), intended for continuous prime duty with regular load swings across panel boards with mixed motor and lighting loads.

Engine options for the 300 kW diesel set are Cummins, Perkins, Weichai and Yuchai; whichever is specified, the engine is matched to the alternator and load-tested in our own works.

The 300 kW package uses closed water-cooling with forced ventilation and a large-capacity tank, holding temperatures steady during extended continuous duty in hot climates.

Enclosure sealing and anti-corrosion finishing are rated IP23 or higher on the 300 kW set, upgradable for harsher sites, treating dust, rain, snow and temperature extremes as normal conditions.

Options on the 300 kW set include an automatic transfer switch, remote monitoring, cable winch and quick connectors; base-frame arrangement and control, protection and voltage settings are set to the project specification.
Standard road-towable trailer unit configuration at 300 kW prime / 330 kW standby (375 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiFor the 300 kW set the engine is drawn from these Tier-1 platforms and matched to the alternator, with the final platform fixed at order stage. |
Control & protectionATS & remote monitoringAn automatic transfer switch and remote monitoring module can be specified on the 300 kW set. The control and protection scheme on the 300 kW set is configured to the project specification. |
Build configurationTrailer-mounted standardTrailer-mounted standard |
1. Production linesProduction lines and compressors is a standard application for the 300 kW unit, which runs at continuous prime duty with regular load swings. Mixed motor and lighting load means the alternator is matched with step-load margin at 300 kW. |
2. HotelsThe 300 kW set is commonly applied to hotels and commercial buildings at continuous prime duty with regular load swings. Shift patterns for the 300 kW set usually mean 12–16 hours a day, so fuel autonomy is calculated on that basis. |
3. DataFor data and telecom rooms the 300 kW rating covers mid-size industrial and site power at continuous prime duty with regular load swings. Compressor and motor starts drive the transient requirement, which is checked against the 300 kW rating. |
4. QuarriesWhere quarries and crushing plants is the load, the 300 kW rating is normally specified at continuous prime duty with regular load swings. Parallel operation on the 300 kW set is often considered where duty is split between two units. |
5. Agricultural processingThe 300 kW trailer-mounted diesel generator set set suits agricultural processing. Duty is continuous prime duty with regular load swings. Sound limits at the boundary usually point to a canopy build at the 300 kW rating. |
6. Site officesSite offices and welfare blocks is a standard application for the 300 kW unit, which runs at continuous prime duty with regular load swings. Cable runs for the 300 kW set are longer, so voltage drop is checked before the final rating is fixed. |
This 300 kW rating is engineered and tested to one standard across the three builds — what changes is enclosure, access and transport.
| This model · 300 kW trailer-mounted diesel generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All trailer-mounted sets |
Tell us the rating, voltage and frequency for the 300 kW unit and we will confirm a configuration.
Send the voltage and frequency you need with the 300 kW rating and the site location, and our engineering team returns a configuration and quotation.