
Heavy-Duty Natural Gas Construction
The 100 kW package is delivered assembled on its base frame, so installation inside or beside the production building is limited to positioning, fuel connection and cabling.
This gas generator set features a standard prime power of 100kW, supporting both continuous grid-connected power supply and emergency backup power modes. It is suitable for various scenarios including small and medium-sized industrial production, commercial buildings, public emergency response, outdoor infrastructure construction and temporary events, providing green and efficient power solutions for enterprises, institutions and project sites to support energy conservation, emission reduction and sustainable operation.
|
100 kW
Prime power
|
|
110 kW
Standby power
|
|
380/220 V
Rated voltage
|
|
2006+
Manufacturer since
|
One natural gas package package, 100 kW prime and 110 kW standby (125 kVA), aimed at small commercial and light industrial.
This 100 kW Natural Gas Generator Set is specified for workshops and repair bays, guesthouses and small clinics, water pumps and irrigation. Typical duty for the 100 kW set is intermittent prime duty with frequent start-stop cycles, feeding light single-unit distribution boards.
Assembly and full-load testing take place on Outevo’s own lines. The company has built diesel and gas sets including this 100 kW class generator sets since 2006 at a 20,000 m² manufacturing facility served by a fully automatic line; over 2,000 sets have shipped to more than 100 countries.
The 100 kW package is protected to IP23 or higher and can be uprated for dust, humidity, rain or heat.

The 100 kW package is delivered assembled on its base frame, so installation inside or beside the production building is limited to positioning, fuel connection and cabling.

Design duty at 100 kW prime and 110 kW standby is continuous running through the working day, which is why the alternator and cooling system are sized for sustained load rather than short standby duty.

The engine is drawn from the Cummins, Perkins, Weichai and Yuchai platforms and matched to the alternator before full-load testing on our own production line.

Closed-circuit water cooling with forced fan and a large water tank is specified because a plant set runs for whole shifts and cannot rely on short cooling recovery periods.

Sealed dustproof, waterproof and anti-corrosion treatment to IP23 or higher, uprated for foundry dust, humid areas or high ambient workshops.

ATS, remote monitoring, cable winch and quick connectors can be specified so the set can be redeployed between bays or buildings as the plant layout changes.
Standard natural gas package configuration at 100 kW prime / 110 kW standby (125 kVA). Ratings, voltage and frequency are confirmed at specification.
Engine platformCummins · Perkins · Weichai · YuchaiEngines on the 100 kW set are selected from the Cummins, Perkins, Weichai and Yuchai platforms and matched to the alternator; the platform for your order is confirmed at order stage. |
Control & protectionATS & remote monitoringOn the 100 kW set an optional automatic transfer switch and remote monitoring module are available, with protection settings configured for continuous prime duty. |
Build configurationNatural Gas standardThis model ships as a silent set. Open frame, containerized and mobile builds of the same rating are available under OEM/ODM terms. |
1. Production lines and machine toolsCarries the whole working-day load of the plant where the grid supply is either absent or too weak to run the line. |
2. Compressors and process pumpsTakes the starting current of large motors and keeps process pumps running without an operator restarting them after each trip. |
3. Furnaces, dryers and ovensHolds process temperature through a shift, which is what prevents scrap and rework when the supply is unstable. |
4. Cold storage and process coolingKeeps refrigeration and cooling loops live, protecting product that would otherwise be lost in a long outage. |
5. Workshop and maintenance baysRuns welding, lifting and compressed-air equipment in the maintenance area independent of the main supply. |
6. Shift-pattern continuous demandSuits plants that work two or three shifts, where the set is the primary source and fuel and service planning follows production hours. |
Whichever build is chosen for the 100 kW rating, engineering and testing are identical; only the enclosure, access and transport change.
| This model · 100 kW natural gas generator set |
| Range · 10–3,750 kVA |
| Diesel & gas |
| Open frame · silent · containerized · mobile |
| All natural gas sets |
Give us the power for the 100 kW set, voltage and frequency and we will come back with a configuration.
Give us the voltage and frequency for the 100 kW set and the destination site; our engineering team comes back with a configuration and quotation.
Our representative will contact you soon.